Showing results: 31 - 45 of 86 items found.
-
Site VSWR -
Seibersdorf Labor GmbH
The Site VSWR measurement is done according to CISPR 16-1-4 in the frequency range from 1 GHz to 18 GHz using broadband omni directional antennas in horizontal and vertical polarisation. The volumetric test method is applied (test volume needs to be specified), test distance 3 m - any other distance upon request. The ground plane has to be covered with absorbing material.
-
KRYTAR, Inc.
KRYTAR MLDD 4-way power dividers lend themselves to emerging wireless ultra-broadband designs and many test and measurement applications. KRYTAR’s power dividers offer the widest frequency coverage in a single package on the market and provides superior performance. Targeting broadband electronic warfare (EW) systems and complex switch-matrix applications, for example, KRYTAR has used its proprietary design to produce a wide assortment of matched-line directional dividers (MLDD) with ultra-high performance over a broadband frequency range. Our 4-way power dividers can also be manufactured to meet military specifications.
-
KRYTAR, Inc.
KRYTAR MLDD 8-way power dividers lend themselves to emerging wireless ultra-broadband designs and many test and measurement applications. KRYTAR’s power dividers offer the widest frequency coverage in a single package on the market and provides superior performance. Targeting broadband electronic warfare (EW) systems and complex switch-matrix applications, for example, KRYTAR has used its proprietary design to produce a wide assortment of matched-line directional dividers (MLDD) with ultra-high performance over a broadband frequency range. Our 8-way power dividers can also be manufactured to meet military specifications.
-
Rosenberger Hochfrequenztechnik GmbH & Co. KG
For microwave measurements and VNA calibrations, Rosenberger develops, manufactures, and provides test & measurement products which meet the highest demands of industrial test applications. These include high-performance VNA test cableswith outstanding phase and amplitude stability, a variety of test port adaptors for VNA applications up to 110 GHz, very robust interchangeable high mating cycle port connector systems, and test devices – from low-frequency devices for simple measurements to components permitting high-precision broadband measurements.
-
TR-069 -
QA Cafe
CDRouter TR-069 is an add-on module for CDRouter that provides test coverage for the Broadband Forum's CPE WAN Management Protocol (CWMP). CDRouter TR-069 incorporates a fully functional Auto-Configuration Server (ACS) and is designed to test a wide range of CWMP client implementations including Internet Gateway Devices (IGD) and LAN-side devices such as set-top boxes (STB) and voice over IP (VoIP) endpoints.
-
EXFO Inc.
Light sources simulate the optical voice, video and data signals of real-life service applications, which is why they are used in various types of tests. Discover a broad range of products that cater to various testing requirements: singlemode or multimode, polarized or non-polarized, broadband or narrowband, tunable, ITU-wavelength-centered and much more.
-
11612B -
Keysight Technologies
The Keysight 11612B broadband high power bias network can be used in a wide variety of biasing applications for test and measurement requirements in laboratory and production environments. Bias networks provide the means of supplying dc bias to the center conductor of the coax connector for your device while blocking the dc to the RF port.
-
11590B -
Keysight Technologies
The Keysight 11590B broadband high power bias networks can be used in a wide variety of biasing applications for test and measurement requirements in laboratory and production environments. Bias networks provide the means of supplying DC bias to the center conductor of the coax connector for your device while blocking the DC to the RF port.
-
11612A -
Keysight Technologies
The Keysight 11612A broadband high power bias network can be used in a wide variety of biasing applications for test and measurement requirements in laboratory and production environments. Bias networks provide the means of supplying DC bias to the center conductor of the coax connector for your device while blocking the DC to the RF port.
-
Keysight Technologies
The Keysight RF and Microwave multiplexer modules for the 34980A Multifunction Switch/Measure Unit offer broadband switching capabilities for switching from DC to 26.5 GHz. Use these modules to route test signals between your device under test and your signal generator, oscilloscope, spectrum analyzer, or other instrumentation. A switch/attenuator driver module also allows control of switches and attenuators external to the 34980A Mainframe.
-
Com-Power Corporation
A typical emi emission test is performed using broadband EMC antennas such as biconical, log periodics, Combilogs and horns. These antennas usually placed at 1, 3 or 10 meter distance as required by the test specification. These is considered far field measurements and the emission limits are given for the specific distance by the specification. During EMI compliance measurements, the emissions levels from products are compared with these limits. If the product exceeds these limits it is considered failing. These tests are typically conducted in a open area test site IOATS) or inside an anechoic chamber.
-
Inframet
TRAL test station is a quasi-universal test station designed to measure parameters of discrete (or small linear array) infrared detectors sensitive in a wide spectral range from about 700nm to about 16 000 nm (NIR/SWIR/MWIR/ LWIR detectors or broadband non selective detectors). All main types of infrared detectors can be tested: photonic detectors: photovoltaic/photoreconductive, cooled/non-coooled, thermal detectors, pyroelectric detectors etc.
-
FLIR GF335 -
Teledyne FLIR
If you need a mobile camera that can detect extremely subtle temperature differences, the FLIR GF335 Broadband is the camera for you. The GF335 is a high sensitivity, low noise, cooled thermal camera that excels at detecting faint heat signatures. It is well suited to a wide range of applications, including use on test ranges, non-destructive testing, research, and science applications.
-
EMCTEST
Meets IEC/EN 61000-4-20, SAE J1752/3, IEC 62132-2 and IEC 61967-2. The GTEM cell is, in principle, a tapered coaxial line (offset septum plate), which is terminated by a hybrid combination of discrete resistors and RF absorbers to achieve a 50 Ohm broadband match. It is applied for Measuring of Emission, Radiated, radio frequency field-immunity test.
-
intec GmbH
No other tester offers so many interfaces and functions: combines all commonly used broadband (xDSL, GPON, LTE) and Gigabit Ethernet interfaces with comprehensive triple-play functions in a single measuring device. It is the integrated all-in-one tester that combines all current test scenarios in one single, multi-functional, handy and intuitively operable device.